News Center
SF6 Decomposition DETERMINATION for powergrid

SF6 Decomposition DETERMINATION for powergrid

Most of the main SF6 sf6-gas decomposition products can be detected optically. Moreover, optical detection can fulfill all requirements of gas detection devices in the power industry, including on-line monitoring and portable detection.

[email protected]
News Detail
  • Byproducts of Sulfur Hexafluoride (SF6) Use in the

    the decomposition products and concentrations formed under actual conditions can vary depending on the equipment used and the type of electrical discharge (CIGRE 1997). 1 CIGRE (the International Council on Large Electric Systems) is a permanent non-governmental and non profit-making international association based in France.powergrid

    Get Price
  • Optical technology for detecting the decomposition

    Most of the main SF6 SF 6 decomposition products can be detected optically. Moreover, optical detection can fulfill all requirements of gas detection devices in the power industry, including on-line monitoring and portable detection.Cited by: 5

    Get Price
  • CN101799458A - Method for analyzing decomposition

    By using the invention, the decomposition products such as SO2F2 in SF6 can be accurately analyzed; and by analyzing the decomposition impurities such as SO2F2, the internal operating condition of...Author: 王宇, 姚唯建, 李丽, 庄贤盛, 黄成吉, 黎晓淀

    Get Price
  • Online detection technology for SF 6 decomposition

    The decomposition component analysis method can be used to monitor and diagnose the insulation state of SF6 electrical equipment in power industry. Here, the authors firstly compared the advantages and disadvantages of various SF6 decomposition products detection methods and analysed their feasibility of online monitoring. Then the requirements of SF6 decomposition products onlineCited by: 1

    Get Price
  • The SF6 Decomposition Mechanism: Background and

    The result shows that: SF6 begins to decompose obviously at 300&C and the main decomposition components contain CO2, SO2F2, SOF2, SOF4, SO2 and H2S; the improvement of

    Get Price
  • Quantitative infrared spectroscopic analysis of SF 6

    A high-performance sensor for detecting SF6 decomposition components (H2S and SOF2) was fabricated via hydrothermal method using Au nanoparticles/tin oxide/reduced graphene oxide

    Get Price
  • Analysis of correlation between Internal discharge in GIS

    Abstract: Gas-insulated metal-enclosed switchgear (GIS) has been widely used in high voltage power grid. At present, the most common fault of GIS equipment is internal discharge, which will bring harm to its insulation. The internal discharge of GIS equipment will cause the decomposition of SF 6 gas.

    Get Price
  • Thermal Decomposition Mechanism of GIS Basin

    resistance to SF6 decomposition gas corrosion, the basin insulator has become a standard insulation component of GIS [1,2]. It can support high-voltage conductors, isolate different gas chambers and insulate from the ground. Therefore, the performance of the basin insulator has been a key factor in identifying the operation status of GIS.

    Get Price
  • Decomposition Properties of C4F7N/N2 Gas Mixture: An

    The insulation characteristics and decomposition components of C4F7N/N2 gas mixture, a potential substitute for SF6, were first explored by breakdown experiments/gas chromatography–mass spectrometer. The structural properties of C4F7N molecule and the decomposition mechanism of C4F7N/N2 gas mixture were analyzed based on the density functional theory calculation and ReaxFF

    Get Price
  • ReCoTec HTV-Extrusion - ReCoTec HTV-Extrusion

    Resistance against various insulation fluids and SF6 decomposition products proven . Design properties - High Flexibility - High resistance against erosion/tracking - Direct molding on customer applications. Power grid imbalance compensation Innovative and smart data collection, analysis and communication; High-Power-Charging.

    Get Price
  • Ultraviolet differential optical absorption spectrometry

    able operation and to the safety of the entire power grid. In this paper, carbon disulfide (CS 2) was chosen as a rep-resentative gas to determine the insulation status of solid Measurement Science and Technology Ultraviolet differential optical absorption spectrometry: quantitative analysis of the CS 2 produced by SF 6 decomposition

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE

    This paper reviews previous research in SF6 decomposition relating to the operation of gas-insulated switchgears, gas-insulated transmission lines, and electrostatic accelerators. Results on the qualitative and quantitative determination of the by-products and their formation ion rates in various modes of electrical discharges are summarized.powergrid

    Get Price
  • The SF6 Decomposition Mechanism: Background and

    Jan 24, 2017Extensive domestic and overseas studies show that when PD occurs in SF 6 gas-insulated equipment, SF 6 will decompose under the effect of electric field energy and generate low fluorine sulfide products such as SF 5, SF 4, SF 3, SF 2, SF, etc. [ 17 ].Cited by: 1

    Get Price
  • Sensitivity Characteristic Analysis of Adsorbent-Mixed

    widely used in the power grid for its advantages of high reliability, small volume, and simple maintenance. Sulfur hexafluoride (SF 6) is used in GIS for its good insulating performance and arc extinction properties [1–4]. The manufacture, transportation and installation process inevitably result in defects in GIS equipment.

    Get Price
  • Decomposition Characteristics of SF6 and Partial

    Experimental results show that the negative DC partial discharges caused by the four defects decompose the SF6gas and generate five stable decomposed components, namely, CF4, CO2, SO2F2, SOF2, and SO2. The concentration, effective formation rate, and concentration ratio of SF6decomposed components can be associated with the PD types.

    Get Price
  • Hierarchical WO3–NiO microflower for high sensitivity

    Hierarchical WO 3–NiO microflower for high sensitivity detection of SF 6 decomposition byproduct H 2S Zhijie Wei1, Qu Zhou1,3 and Wen Zeng2,3 1College of Engineering and Technology, Southwest University, Chongqing 400715, People’s Republic of China 2College of Materials Science and Engineering, Chongqing University, Chongqing 400044, People’s Republic of China

    Get Price
  • Development of a suitcase time‐of‐flight mass spectrometer

    Sulfur hexafluoride (SF 6) gas‐insulated switchgear (GIS) is an essential piece of electrical equipment in a substation, and the concentration of the SF 6 decomposition products are directly relevant to the security and reliability of the substation. The detection of SF 6 decomposition products can be used to diagnosis the condition of the GIS.

    Get Price
  • Development of a suitcase time-of-flight mass spectrometer

    The detection of SF6 decomposition products can be used to diagnosis the condition of the GIS. METHODS: The decomposition products of SO2, SO2 F2, and SOF2 were selected as indicators for the diagnosis. A suitcase time-of-flight mass spectrometer (TOFMS) was designed to perform online GIS

    Get Price
  • SF Recycling Guide - epa.gov

    6 and its decomposition products in gas insulated switchgear” ELECTRA, No. 136 and 137 (1991) This document was the basis for: “IEC Standard 1634: High voltage switchgear and control gear - Use and handling of sulphur hexafluoride in high voltage switchgear and control gear,” 1995powergrid

    Get Price
  • Decomposition mechanism of the C5-PFK/CO2 gas mixture

    Mar 15, 2018The investigation of the decomposition characteristics of gas-insulated medium is an important measure of their application reliability. Tatarinov et al. explored the decomposition properties of C5-PFK/air or N 2 gas mixture by dielectric barrier discharge. The main decomposition products of C5-PFK are CF 4, C 4 F 10, C 6 F 14, C 3 F 6, and C 3

    Get Price
  • CN103105441B - Qualitative and quantitative analysis

    The detection on the SF6 decomposition product assists in an operator to know the insulating state inside electrical equipment so as to judge failure causes accurately. The invention discloses a...powergrid

    Get Price
  • First-principles study of Pd-MoSe2 as sensing material for

    Dec 10, 2019SF 6 decomposition component detection is an effective way to diagnose the severity and type of electric discharge. In this study, MoSe 2 based material has been chosen as the gas sensing material for the detection of SOF 2 and SO 2 F 2, the two characteristic decomposition components of SF 6.

    Get Price
  • Paskals Fluid Systems Pvt. Ltd.

    At high temperature, during electric arcing for example, SF6 can slowly decompose. Such decomposure produces byproducts which will react with moisture to pro- duce a variety of substances. These substances, together with decomposition byproducts, can be extremely corrosive and toxic.powergrid

    Get Price
  • Sulfur hexafluoride | F6S - PubChem

    Sulfur hexafluoride is a sulfur coordination entity consisting of six fluorine atoms attached to a central sulfur atom. It is the most potent greenhouse gas currently known, with a global warming potential of 23,900 times that of CO2 over a 100 year period (SF6 has an estimated lifetime in the atmosphere of between 800 and 3,000 years).powergrid

    Get Price
  • Electrochemical sequential reduction and oxidation

    Feb 15, 20201. Introduction. SF 6 has key applications in gas phase arc-quenching current interruption instruments in power grid sectors and semiconductor production field, but it is considered a potent greenhouse gas because of its extreme inertness .Until other alternatives to SF 6 gas in high voltage circuit breakers and insulators in semiconductor industry become available, the use of SF 6 in the

    Get Price
  • Simulation and experiment on the catalytic degradation of

    The high-temperature effect gas SF 6 is used in the power industry, and its emissions are increasing daily. Therefore, the degradation of SF 6 is particularly important. In this work, SF 6 with a high concentration of 2% was degraded using the catalytic principle of TiO 2 under UV light at normal temperature and pressure. Experimental results proved that this method can effectively degrade SF 6.

    Get Price
  • SF6 positive DC partial discharge decomposition

    Hence, this paper mainly looks at the role of the five decomposition products of SF 6 uniformed in the gas chamber, namely, CF 4, CO 2, SO 2 F 2, SOF 2 and SO 2. 3.1 Decomposition rules and comparison of carbon‐containing characteristic decomposition components. Fig. 4 shows how CF 4 varied with time in AC experiment.powergrid

    Get Price
  • OSA | Highly sensitive and selective CO sensor using a 2

    A ppm-level CO sensor based on a 2f wavelength modulation spectroscopy (2f-WMS) technique was developed for the application of SF6 decomposition analysis in an electric power system. A detailed investigation of the optimum target line selection was carried out to avoid spectral interference from high purity SF6 in a wide wavelength range. A diode laser emitting at 2.33 #x03BC;m and a 14.5-m

    Get Price
  • Adsorption and Gas Sensing Properties of the Pt3-MoSe2

    Download MS PowerPoint Slide SF6acts as an insulation gas in gas-insulated switchgear (GIS), which inevitably decomposes under partial discharge caused by insulation defects. This work is devoted to finding a new gas-sensing material for detecting two characteristic SF6decomposition products:

    Get Price
  • Switchgear Condition assessment services | EA Technology

    Assessment of Sulphur Hexafluoride (SF6) gas insulation. Decomposition products arise during operation of SF6 gas-insulated switchgear through arcing in moist or impure SF6 gas. Testing the gas for impurities will therefore indicate potential issues with the switchgear. More

    Get Price
  • Assessment of SF6 Gas Insulation | EA Technology

    Assessment of Sulphur Hexafluoride (SF6) gas insulation. Testing SF 6 gas for impurities will therefore indicate potential issues with the switchgear.. Decomposition products arise during operation of SF 6 gas-insulated switchgear through arcing in moist or impure SF 6 gas. Testing the gas for impurities will therefore indicate potential issues with the switchgear.

    Get Price
  • Insights on decomposition process of c-C4F8 and c-C4F8/N2

    It was found that the decomposition of c-C 4 F 8 /N 2 mainly produces CF 2, F, CF 3, CF, C, CF 4 and C 2 F 4. c-C 4 F 8 can decompose to C 2 F 4 by absorbing 43.28 kcal/mol, which is the main decomposition path and this process easily occurs under high temperature. There is a dynamic equilibrium process among the various produced radicals

    Get Price
  • Analysis of SF6 decomposition products by insulator

    An evident fault occurs on the insulator surface accompanied by a remarkable insulator strength decline were detected, which is probably caused by the SF<sub6</sub decomposition products in the insulator flashover process. A simulation of flashover process on the insulator surface was built in this article in order to analyze the possible decomposition product of SF6.

    Get Price
  • Development of a suitcase time-of-flight mass

    Development of a suitcase time-of-flight mass spectrometer for in situ fault diagnosis of SF 6-insulated switchgear by detection of decomposition products Keyong Hou1, Jinxu Li1, Tuanshuai Qu1, Bin Tang2, Liping Zhu2, Yunguang Huang2 and Haiyang Li1* 1Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of

    Get Price
  • The Problem with Humidity in SF6 Gas-Insulated Systems

    Sulfur hexafluoride (SF6) has excellent dielectric capabilities and is widely used as an insulator in power grid switchgear. Humidity in SF6 gas, however, can decrease its insulation strength, promote corrosion, and cause failures.

    Get Price
  • Sensitivity Characteristic Analysis of Adsorbent-Mixed

    Sulfur hexafluoride (SF6) gas decomposition results from the energy produced by partial discharge (PD). The detection of SO2and H2S content, as important characteristic components of the decomposition products, is significant in the determination of the insulation level of SF6gas and the inside insulation faults of gas-insulated equipment.

    Get Price
  • Switchyard design overview - SlideShare

    Oct 18, 2014However it disintegrates to other fluorides of Sulphur in the presence of arc. but after the extinction of the arc the SF6 gas is reformed from the decomposition.SF6 being non-flammable so there is no risk of fire hazard and explosion. The construction and working principles of SF6 circuit breaker varies from manufacturer to manufacturer.

    Get Price
  • Theoretical Analysis of the Decomposition Pathways and

    Oct 10, 2020C6F12O (1,1,1,2,2,4,5,5,5-nonafluoro-4-(trifluoromethyl)pentan-3-one) is one of the most potential alternative insulation medium to SF6 due to its excellent electrical strength and environmental effect. Although several works on the insulation and decomposition properties of C6F12O have been carried out in recent years, the detailed decomposition pathways and mechanism of C6F12O haven’t

    Get Price
  • SF6 decomposition detection systems rental

    SF6 decomposition detection systems rental. Point Group Of Sf6 - gqe.area-test.it iSF6-716 laser leak detector is based on photo-acoustic spectroscopy (patented technology) has reached a high level of sensitivity at 0. top sf6-gas circuit in DENMARK. Today, most sf gas analyzers have the ability to measure purity and humidity and Dew/Frost Pointpowergrid

    Get Price
  • Products - Huazheng Electric Manufacturing (Baoding) Co

    Huazheng Electric Manufacturing (Baoding) Co.,Ltd is one of the leading cable locator, transformer oil tester, transformer tester, high voltage tester manufacturers China, welcome to import cheap and discount cable locator, transformer oil tester, transformer tester, high voltage tester from us. - Page 23

    Get Price
  • Detection of Ozone and Nitric Oxide in Decomposition

    Air-insulated switchgear cabinets play a role in the protection and control of the modern power grid, and partial discharge (PD) switchgear is a long-term process in the non-normal operation of one of the situations; thus, condition monitoring of the switchgear is important.

    Get Price
  • electrochemical sensors technology - MAFIADOC.COM

    A simulation of Pd-doped SWCNTs used to detect SF6 decomposition components under partial discharge. Applied Surface Science. 2014;315:196-202 [43] Zhang X, Chen Q, Tang J, Hu W, Zhang J. Adsorption of SF6 decomposed gas on anatase (101) and (001) surfaces with oxygen defect: A density functional theory study.

    Get Price
  • sf 6 o2 control of emissions manufacturer

    SF 6 o2 control of emissions manufacturer. Jan 01, 2015Reducing Sulfur Hexafluoride (SF6) Emissions from Gas-Insulated Switchgear (310 CMR 7.72) SF6 is a strong greenhouse gas (GHG), with a global warming effect nearly 24,000 times greater than carbon dioxide. SF6 also lasts in the atmosphere for more than 3,000 years after it [email protected]powergrid

    Get Price
  • SF6 End-of-life Recovery of Polluted

    SF6 End-of-life Recovery of Polluted. Sulfur hexafluoride, SF 6, is used around the world as a dielectric medium for high-voltage circuit breakers, switchgear, and other electrical equipment.Additionally, it is used for the filling of insulated windows and for the casting of magnesium.powergrid

    Get Price
  • Application of On-line Detection Technology in Shanghai

    Explored Works in Shanghai Power Grid . The state gird suggests to generalize the on-line detection method on those major equipments in power system such as transformers, insulating bushing, current and voltage transformers, coupling capacitor, arrester, switchgear, open-type SF6

    Get Price
  • Power IT Lab - Selected Publications

    F. Liu, Mathematical Model of Influence of Oxygen and Moisture on Feature Concentration Ratios of SF6 Decomposition Products, Proc. IEEE Power Eng. Soc. Gen. Meeting, 2012. [41] P. N. Markham, Analysis of Frequency Extrema in the Eastern and Western Interconnections, 2010-2011, Proc. IEEE Power Eng. Soc. Gen. Meeting, 2012.

    Get Price
  • IET Digital Library: Effects of voltage forms, pressure

    An experimental and testing platform was established to comparative study the decomposition characteristic of SF6 under different voltage waveform (negative direct current (DC) voltage, positive DC voltage, and alternating voltage), and investigate the influence of pressure and adsorbent. Content variation of typical products under different conditions and the influence mechanism were observed

    Get Price
  • An alternative to SF6 in electrical switchgear - EE Publishers

    For decades, the unique properties of sulfur hexafluoride (SF6) have made it popular as an insulation and switching medium for electrical switchgear. However, SF6 is a greenhouse gas and there are life-cycle management costs associated with its use. For some years, ABB has been conducting research into alternatives with lower environmental impact but with […]

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online